• High impact resistant board for interior wall applications.

High impact resistant board for interior wall applications.

KalsiPartition is the ideal solution for the most demanding internal wall applications subject to high traffic or humid conditions.

KalsiPartition  provides excellent acoustic insulation. The inclusion of mineral wool in the wall cavity improves both thermal and acoustic performance.

All kinds of conduit, wiring, pipe and other services are easily installed in the cavity of every KalsiPartition system.

Recommended Application

  • Partitions in wet areas like Industrial kitchens, labs, washrooms and bathing areas
  • High traffic locations of hospitals, corridors, shopping centres and schools

Benefits

  • Resistant to the attack of termites, insects and other vermin
  • Moist, mould and water resistant
  • Wide variety of thicknesses and applications
  • Impact resistant
  • Dimensionally stable
  • Easy to work and install

Surface finishes

KalsiPartition is resistant to impact, moisture and fire. It is the ideal solution for high traffic areas.

Technical Properties

KalsiPartition 8, 9 Standard dimensions

Thickness
(mm)
Width
(mm)
Length
( mm)
Weight per m² of sheet
(kg/m²)
8 1200 2400 11.36
8 1220 2440 11.36
8 1200 2700 11.36
8 1200 3000 11.36
9 1200 2400 12.78
9 1220 2440 12.78
9 1200 2700 12.78
9 1200 3000 12.78

*Other dimensions are available upon request. The properties in above tables are mean values given for information and guidance only. If certain properties are critical for a particular application, it is advisable to consult Kalsi.

KalsiPartition 8, 9 Physical and mechanical properties

General Technical Properties Value Standard
Dimension conformity
• Thickness
• Length
• Width
• Straightness of edges
• Squareness of edges
Level II
(Pass)
ISO 8336: 2009
Density (average) > 1250 kg/m³ ISO 8336: 2009
Bending strength (Category C) > 10 MPa (Class 3) ISO 8336: 2009
Bending Elastic Modulus (ambient) > 8500 MPa ISO 8336: 2009
Water absorption 33 ± 2 % ASTM C1185
Moisture content 10 – 15 % ASTM C1185
Moisture movement ≤ 0.04 % ISO 8336: 2009
Thermal conductivity 0.25 W/mK ASTM C518: 2010
Durability
Heat-rain performance Not required ISO 8336: 2009
Warm water performance Passed ISO 8336: 2009
Soak-dry performance Passed 50 cycles ISO 8336: 2009
Freeze-thaw performance Not required EN 12467: 2016
Reaction to Fire
Non-combustibility Non-combustible BS 476 Part 4: 1970
Surface spread of flame Class 1 BS 476 Part 7: 1997
Fire propagation index I = 2.3
i(1) = 2.1
i(2) = 0.1
i(3) = 0.1
BS 476 Part 6: 1989
Heat Emission Pass BS 476 Part 11: 1982
Fire classification using test data from reaction to fire test Class A1 EN 13501-1: 2007 + A1: 2009

Installations Practices.

  1. KalsiPartition
  2. Steel stud
  3. Drywall screw
  4. Multipurpose joint compound
  5. Corner bead
  6. Horizontal channel
  7. Polyurethane (PU) sealant​
  8. 6mm backer rod
  9. 50mm fibreglass mesh tape